Rated Voltage | 220 V |
Frequency | 50 Hz. |
Rated Output | 1. 5 kVA (continuous) / 10 kVA 60 min. 2. 10 kVA (continuous) / 20 kVA 60 min. |
Frequency | 50 Hz. / 60 Hz. |
Inductance | 30mH - 15 mH |
Dimension | 425 x 462 x 190mm |
Weight | 100 kg |
Test Out put of the Transformer in Cascade Connection |
||||||||||
Without compensation for transformer TEO 100/10 | With compensating reactor for transformer TEO 100/10 | Without Compensation for transformer TEO 100/20 | With compensating reactor for transformer TEO 100/10 | |||||||
Cascade | Cont. | Short Time | Cont. | Short Time | No. of reactors | Cont. | Short Time (approx) |
Cont. | Short Time (approx) |
No. of reactors |
Single Stae | 5kVA | 10kVA | - | - | - | 7.5kVA | 20kVA | - | - | - |
Two Stage | 5kVA | 10kVA | 10kVA | 20kVA | 1 | 7.5kVA | 20kVA | 12.5kVA | 30kVA | 1 |
Three Stage | 5kVA | 10kVA | 15kVA | 30kVA | 2 | 7.5kVA | 20kVA | 17.5kVA | 40kVA | 2 |